Akzo Nobel Aerospace Coating - Home Page
Contact Akzo NobelContact Akzo Nobel
                  
About Akzo Nobel Aerospace Coatings Our Markets News and Publications Health and Safety Products Troubleshooting Frequently Asked Questions
Equipment Troubleshooting: Streaks

Cause
- Dirty air cap and fluid tip (distorted spray pattern)
- Insufficient or incorrect overlapping of strokes
- Gun stroked to rapidly(dusting of the paint)
- Gun stroked at wrong angle to surface
- Stroking to far from surface
- Too much air pressure
- Split spray

Prevention
- Remove air cap and clean tip and air cap carefully
- Follow the previous stroke accurately. Deposit a wet coat.
- Avoid whipping. Make deliberate slow strokes
- Keep gun at right angle (perpendicular)to surface during stroke
- Maintain 15-25 cm (conventional) or 35 –45 cm (airless) distance to surface
- Use least air pressure necessary
- Clean the fluid tip and air cap

Remedies
- Strip and clean or sand down and repaint